Model : Hawkeye FLP-RTC

  1. 3 Channel RH, Temperature & DP measurement
  2. Potential free Digital Input for AHU status
  3. Suitable for 50mm modular panel
  4. Real Time Clock with battery Backup
  5. 3 programmable Alarms with visual annunciation
  6. No-touch operation for Alarm Acknowledge
  7. 3 x 4-20mA or 0-10V analog output
  8. RS485 / Modbus RTU
  9. 18-35 VDC supply
  10. 4 row, 0.56” seven segment Display
  11. Datalogging
  12. Process Value, Alarm and Time Stamp Logging
  13. Memory for 31 days with 1 minute datalogging interval
  14. Full datalogging control through utility
Read More...

Hawkeye RTC Flameproof Clean Room Monitor

3 x Integral, Slave, Remote

Potential free AHU digital input

Buzzer Output

3 Analog Output

20-35 VDC Supply

3+3+3+4 (0.560)

modbus TCP, Telnet

21 days datalogging

vRadix RTC Ethernet HAWKEYE Clean Room Monitor is a high-performance monitoring solution equipped with Ethernet (Modbus TCP/IP) connectivity for seamless integration with BMS, SCADA, or DCS systems. Designed for cleanrooms, pharma units, and regulated environments, it features a bright 2-row, 3-row, or 4-row LED display to show real-time parameters such as Temperature, Relative Humidity, Differential Pressure, Air Velocity, and more. Powered by a 32-bit microprocessor, the device ensures fast, accurate readings and offers 21-day onboard data logging for audit trails

Hawkeye RTC Flameproof Clean Room Monitor

Hawkeye RTC Flameproof Clean Room Monitor

Similar Products

product Clean Room Monitor, With RTC
Clean Room Monitor, With RTC |Hawkeye-RTC

  1. 3 Channel RH, Temperature & DP measurement
  2. Potential free digital input for AHU status
  3. Real time clock with battery backup
  4. 3 programmable alarms with visual annunciation
  5. No-touch operation for Alarm Acknowledge
  6. 3 x 4-20mA or 0-10V analog output
  7. RS485/Modbus RTU
  8. 18-35 VDC supply
  9. 4 row, 0.56” seven segment Display
  10. Datalogging feature
  11. Process value, alarm and time stamp logging
  12. Memory for 31 days with 1 minute datalogging interval
  13. Full datalogging control through utility
Read More...

product Flameproof Clean Room Monitor, 3 Row
Flameproof Clean Room Monitor, 3 Row |Hawkeye FLP-3 Row

  1. RH, Temperature & DP measurement
  2. 3 programmable Alarms with visual annunciation
  3. No-touch operation for Alarm Acknowledge
  4. Suitable for 50mm modular panel
  5. RS485/Modbus RTU multidrop communication for PLC, SCADA, etc.
Read More...

product Clean Room Monitor, 3-Row Display, Ethernet & Datalogging in CSV files
Clean Room Monitor, 3-Row Display, Ethernet & Datalogging in CSV files |Hawkeye-3 Row, Ethernet

  1. 3 Channel RH, Temperature & DP measurement
  2. Potential free Digital Input for AHU status
  3. 3 programmable Alarms with visual annunciation
  4. No-touch operation for Alarm Acknowledge
  5. 3 x 4-20mA or 0-10V analog output
  6. 18-35 VDC supply
  7. 3-digit, 0.8” seven segment Display
  8. Ethernet / Modbus TCP
  9. Datalogging for 21 days, 1 CSV file per day
Read More...

product RTC Clean Room Monitor, Ethernet & Datalogging in CSV files
RTC Clean Room Monitor, Ethernet & Datalogging in CSV files |Hawkeye-RTC, Ethernet

  1. 3 Channel RH, Temperature & DP measurement
  2. Potential free Digital Input for AHU status
  3. Real Time Clock with battery Backup
  4. 3 programmable Alarms with visual annunciation
  5. No-touch operation for Alarm Acknowledge
  6. 3 x 4-20mA or 0-10V analog output
  7. 18-35 VDC supply
  8. 4 row, 0.56” seven segment Display
  9. Ethernet / Modbus TCP
  10. Datalogging for 21 days, 1 CSV file per day
Read More...

Customers Also Viewed

product 2-wire Temperature Transmitter
2-wire Temperature Transmitter |TX1HM

  1. RTD Pt100, 3-wire input
  2. 2-wire, 4~20mA analog output
  3. 8 SPAN ranges, 25 to 600 C° / 45 to 1080 F°
  4. 4 ZERO ranges, -100 to +70 °C / -148 to +158 °F
  5. Accurate : 0.1% temperature linear
Read More...

product Three Phase Two Leg Zero Cross SCR Power Regulator, 50-200 A
Three Phase Two Leg Zero Cross SCR Power Regulator, 50-200 A |TPR-3P-48xxx-2z

  1. Zero Crossover control technology
  2. 4-20 mA / 0-10 V / 2-10 V / 0-5 V / 1-10 V control input
  3. Suitable for 3-phase resistive load
  4. Configuration : 3-phase star without neutral / closed delta
  5. Adjustable power control
Read More...

product Dual/Triple Differential Pressure Indicator® With Ethernet Port/Modbus TCP
Dual/Triple Differential Pressure Indicator® With Ethernet Port/Modbus TCP |DPG214

  1. 2, 3 or 4-row, large, bright red LED display
  2. IP65 (NEMA 4X) front
  3. 2 programmable alarms with audio-visual annunciation
  4. Guaranteed back-up against Ethernet/SCADA/computer failures
  5. Supports Modbus TCP Protocol to get data using Modbus TCP client on SCADA/PLC/HMI
  6. 4 x Modbus TCP clients supported at a given time (multi-master/multi-host)
  7. FTP as an open standard protocol - instrument can be used by a third party system integrator with any SCADA or PLC or HMI
  8. 3 x FTP clients supported at a given time with 180 seconds internal FTP connection timeout
  9. 21-days data can be stored with any datalogging interval
  10. Adjustable data storage interval via browser web page (1-1440 minutes)
  11. Data is in CSV format and easy to use
  12. Ethernet related firmware can be updated over Ethernet
Read More...

product 2-8 Door Interlock System - 8 Door Controller
2-8 Door Interlock System - 8 Door Controller |DXC281

  1. 1) External voltage: 100-240 V AC/1.8A (60Hz)
  2. Internal voltage : 12V/6.25A
  3. 4 General purpose inputs
  4. 2 General purpose relay outputs and 8 Relay outputs for magnetic locks.
  5. Dimensions (in mm): 360(L) x 325(W) x 80(H)
  6. Material: MS, Powder coated
  7. Mounting: Wall
  8. Relative humidity:5-95% RH, non-condensing